Electrical operation & Maintenance Engineer with 11 Years of experiences


Last Updated: 16th September 2020 (over 2 years ago)

Address
United Kingdom

E-mail
Locked

Phone Number
Locked

Gender
Male

Age Range
35 to 44

Qualification Level
Degree

Languages
Arabic, English, Gujarati, Hindi

Summary

SNAPSHOT:
 GCC experienced Electrical Engineer with 11 years of experience in petrochemical industry, preliminarily focus on Operation, troubleshooting & maintenance of switchgear, transformer, HT Motors, control system and protective equipment (230KV GIS,132KV GIS, 34.5KV GIS, VCB, MCC, VFD, PLC, GE-Multiline 469, 239 motor manager relay, DG sets, UPS, ETAP load flow and short circuit analysis.)
 Siemens Certification in 230KV SF6 Gas Insulated substation, breaker operation and maintenance.
 Siemens Certification in SIPROTEC – Protection relay.
 ETAP Certification - Load Flow and Short Circuit, Arc Flash study, Harmonic analysis, Relay coordination.
 Member of Saudi Council of Engineer.
 Familiar with SADARA chemical (Saudi Aramco & Dow chemical joint venture) operation and maintenance work process like SADARA Turnaround Methodology, Lock-Out Tag-Out (LOTO), ERP-SAP, Operation Dash Board (OPD), Compliance Task Tool, E Logbook, RTMS, Dow/SADARA Management Of Change (Web - MOC) & Opportunity tracking system.
 Well understanding about ANSI, NFPA70, IEC Safety electrical standards and installation, repair of electrical equipment installed in Hazardous area.
 Hands On Experience -
• Siemens Gas Insulated Switchgear (GIS) - 8DN9,8DA10
• High Voltage Switchyard Equipment – Live Tank CT, Dead Tank CT, Isolators, Lightning Arrestors, HT Cables, Transformers, Harmonic Filter (with ETAP calculation)
• VFD – Siemens Master Drive, Micro-mater, Mini-Master, Sinamics, ABB- ACS600,800,550
• Protection Relay - Siemens Siprotec -7SJ60, 6MD664, SIMOCODE, GE-Multiline 469.
• PLC – Allen Bradley, Siemens
• DG Set – 2.3MW Wartsila, 2MW Cummins, 1MW MTU.

Education

Dr. Babasaheb Ambedkar Technological University
Bachelor Of Electrical Engineering

   Jun 2004
— Jun 2007

Bachelor Of Electrical Engineering
1. Electrical Machines
2. Power Generation
3. Electrical Switch-gear
4. Electrical Protection
5. Microprocessor
6. Transmission & Distribution

Experience

Sadara chemical company
Sr Power Distribution production activity coordinator - Electrical Engineer

   Apr 2013
— Apr 2019

 Operation, troubleshooting and maintenance of 230KV, 34.5KV, 132KV SF6 GIS High voltage switchgear.
 Operation and troubleshooting of DILO SF6 gas filling machine used for GIS High voltage switchgear.
 Expert in remote and local operation of high voltage switching equipment (Isolator, earthlings switch, High speed earthling switch, main circuit breaker).
 Designing, testing and troubleshooting of Main-Tie-Main(MTM), Auto Transfer Scheme (ATS), Auto Mains Fail (AMF) and Fast bus transfer scheme (FBT).
 Preventive and breakdown maintenance of transformer up to 240MVA along with tap changer and DGA.
 Exposure to troubleshooting, testing of Siemens, SEL, GE Multiline make protection relay (7SJ60, 7SJ80, 7VH60, 7SD522, 6MD664, GE-Multiline 469, Siemens SIMOCODE).
 Extensive knowledge about programming, and troubleshooting of Siemens, ABB make variable frequency drive (VFD – Siemens Master Drive, Micro-mater, Mini-Master, Sinamics, ABB- ACS600,800,550).
 Provide the recommendation for repair work or upgradation of substation electrical equipment (UPS, battery bank, battery charger, HVAC, MCC, VCB, ACB, HT and LT panels).
 Responsible for operation, readiness, troubleshooting and preventive maintenances of black start emergency DG set (2.3MW Wartsila, 2MW Cummins, 1MW MTU).
 Maintenance, overhauling, and testing of induction motor.
 Preparation of shutdown plan for major electrical equipment (240MVA transformer, 7.5MVA VFD, 16MVA Motor), Coordination with site integration team for optimizing the turnarounds time.
 Preparation of high voltage as well as low voltage Electrical switching order for change over and isolation of electrical equipment.
 Preparation of LOCK OUT-TAG OUT (LOTO) procedure for isolation.

Supreme Petrochemical Ltd
Deputy Manager Electrical

   Aug 2008
— Feb 2013

 Operation, troubleshooting and maintenance of 230KV, 34.5KV, 132KV SF6 GIS High voltage switchgear.
 Operation and troubleshooting of DILO SF6 gas filling machine used for GIS High voltage switchgear.
 Expert in remote and local operation of high voltage switching equipment (Isolator, earthlings switch, High speed earthling switch, main circuit breaker).
 Designing, testing and troubleshooting of Main-Tie-Main(MTM), Auto Transfer Scheme (ATS), Auto Mains Fail (AMF) and Fast bus transfer scheme (FBT).
 Preventive and breakdown maintenance of transformer up to 240MVA along with tap changer and DGA.
 Exposure to troubleshooting, testing of Siemens, SEL, GE Multiline make protection relay (7SJ60, 7SJ80, 7VH60, 7SD522, 6MD664, GE-Multiline 469, Siemens SIMOCODE).
 Extensive knowledge about programming, and troubleshooting of Siemens, ABB make variable frequency drive (VFD – Siemens Master Drive, Micro-mater, Mini-Master, Sinamics, ABB- ACS600,800,550).
 Provide the recommendation for repair work or upgradation of substation electrical equipment (UPS, battery bank, battery charger, HVAC, MCC, VCB, ACB, HT and LT panels).
 Responsible for operation, readiness, troubleshooting and preventive maintenances of black start emergency DG set (2.3MW Wartsila, 2MW Cummins, 1MW MTU).
 Maintenance, overhauling, and testing of induction motor.
 Preparation of shutdown plan for major electrical equipment (240MVA transformer, 7.5MVA VFD, 16MVA Motor), Coordination with site integration team for optimizing the turnarounds time.
 Preparation of high voltage as well as low voltage Electrical switching order for change over and isolation of electrical equipment.
 Preparation of LOCK OUT-TAG OUT (LOTO) procedure for isolation.

Ad