Summary

I have experience in operation and maintenance of substation and erection ,testing and commissioning of 33KV/11kv substation and Overhead and under ground transmission line up to 33kv. Also i have experience in maintenance of Oil and dry type transformer, Motor, soft starter,AC drives, PLC programming ,USS,PSS,MCC ,PCC,Battery Charger,UPS,Circuit breaker,RTU,Current transformer,Potential transformer,Isolater,LA.
I have experience in maintenance of state of art steel plant where i came across the maintenance of rolling mill ,down collier supplied by SMS demac. SEMADYNE-D. etc.

Education

Yeshwantrao Chavan College of Engineerinng
Bachelor Degree in Electronics and Power Engineering (ie Electrical Engineering)

   Aug 1996
— May 2000

It is a 4 Year Degree course in which total 26 subjects is covered out of that some of them is , It starts from fundamental of Electrical Engineering ,Electrical Machine , High voltage engineering,Network theory, Control system engineering, Electrical Machine design ,Power Electronics, Electronics devices and circuits,Electrical Measuring instrument, Electro Magnetic Field,Electrical Power system.

Experience

Kirloskar Electric Company Ltd.
Senior Electrical Engineer

   Mar 2016
— Mar 2017

Roles & Responsibilities :( years experience)
Worked as a Senior electrical engineer & HOD Maintenance since from 05/03/2016 to 08/03/2017 . looked service department allover India ,The product is Cast resin Dry type transformer. Giving technical support to the customer ,solving problems of Customer, Supply of Spares and Coils of transformer from 433Volts to 33KV.Cordination with different department like Engineering Design,Marketing,PMD,MMD,Production & Maintenance Department. Etc.
As a maintenance HOD I look after plant maintenance, preventive maintenance of 22KV/0.433KV 10MVA substation, circuit breaker ,CT, PT,LA, APFC panel, relay and control panel,PCC,MCC , etc.

Siemens Ltd
Electrical Engineer Mainntennance

   Dec 2013
— Dec 2015

Roles & Responsibilities :( years experience)
Worked as an electrical engineer since from 02/12/2013 to 01/12/2015 . Operation and Maintenance of 11KV distribution network,11/0.433KV 2.5 MVA substation.300KVA,250KVA UPS, Battery Charger ,HT & LT PCC ,MVPCC,MCC, VCB ,ACB transformer, CT ,PT, HT & LT Motors.
Having experience of maintenance of RTU panel,S7 400 Siemens PLC,VFD.

Khed Economic Infrastructure Pvt. ltd
Electrical Site Engineer

   Aug 2011
— Aug 2013

Roles & Responsibilities :( years experience)
Worked as an electrical engineer since from 12/08/2011 to 27/08/2013. Having experience in erection testing, ,commissioning work of 33kv,11kv transmission & distribution line,& 2x5MVA 33KV/11KV substation at khed SEZ

1. Construction of transmission line, Supervision of erection and commissioning, site co-ordination.
2) Execution of Overhead Lines, DP structures and Co-ordination for new substation activities.
3) Liasioning with MSEDCL
4) Facilitating other functional area in their works & Cost Efficiency measures.
5) Monitoring of Electrical works at substation.
6) Solving ROW problem.
7) Monitoring and reporting the progress of electrical activities like DPR.
8)Taking Measurements of equipment ,material at site.

JBS Enterprises Pvt. Ltd.
Electrical Engineer Mainntenance

   Jul 2010
— Aug 2011

Roles & Responsibilities :( years experience)
Worked as an electrical engineer since from 21/07/10 to 08/08/2011. Having experience in operation and maintenance of 110KV/33Kv Main Receiving station at LAVAS(PUNE) , Operation and maintenance of 33KV ,11KV distribution substation network ,RMU panel ,USS ,PSS etc.. Done the maintenance of 110KV SF6 Crompton Greaves CB,CT,PT,LA,ISOLATORS,2 X 25 MVA transformers, Done the testing of 33kv/11kv 10MVA transformer & 11KV/433v transformers for open circuit test ,short circuit test, magnetic balance test, vector group test ,meggering and ratio test. Look after testing of relay for primary injection and secondary injection etc..
• Preparation of document like Daily Management record ,Daily Energy report etc.
• Preparation of MIS reports .
• Planning daily maintenance activities
• Attending condition based maintenance etc.
• Managing Site Activities promptly & effectively.

Ispat Industries Ltd.
Senior Electrical Engineer Maintenance

   May 2006
— Mar 2009

Roles & Responsibilities : ( years experience)
Worked as Senior Engineer since from 11 May 2006 to 11 march 2009 on responsibility of shift in-charge. Came across day to day maintenance, preventive maintenance , productive maintenance of plant . operation and maintenance of transformer ,HT & LT motors, AC & DC motors, Siemens S7 plc system, Win-CC, HMI,AC & DC drives, HT & LT power distribution

1) Installation, testing and commissioning of 37MVA SMS ladle furnace transformer ,33kv SF6 circuit breaker
2) Re Installation and re commissioning of 50 TPD oxygen plant:- Came across HV supply termination of 1060kw air compressor & 290kw oxygen compressor of 3.3KV .Also wiring of its auxiliary equipment. Relay panel wiring continuity checking of over current ,instantaneous over current ,under voltage ,motor protection relay of English electric Company , Wiring of field instrument pressure transmitter, pressure indicator, pressure and differential pressure gauge ,Flow meter, flow transmitter ,flow control valves, RTD’s temperature recorder from field to JB and from JB to interfacing module of HITACH PLC system.. Also check the oil level indicator , temperature gauge of oil and winding for its alarm and tripping indication of transformer.
3) 300 TPD Lime calcinations plant project:- Cable and wire laying of HT ,LT and multi core control cable from MCC to field equipment like Cooling air blower, west gas filter suction fan, coal dust dosing rotary valves, skip hoist vvvf with breaking resistor, Vibro feeder motor, combustion air blower, lance cooling blower, hydraulic pump, combustion air blower, filter fan for coal silo dol starter its lugging , crimping and termination. Wiring of Sematic S7 plc panel and field equipment like proxy, limit switch etc.

Salasar Aloys and steel Industries Pvt. ltd.
Electrical Maintenance Engineer

   Mar 2005
— Apr 2006

Roles & Responsibilities :( years experience)
Worked as an Electrical Engineer from 16/03/05 to 29/04/06 look after maintenance of 2800KW induction furnace, LDO and FO tank electrical system, 33 kv switch yard and two 20 tone EOT crane. Come across erection and commissioning of 33kv SF6 circuit breaker for capacitor bank switching duty .Also look after availability of spare’s in store for emergency and daily maintenance

MSEB EHV O&M Division (220KV Main Receiving Station)
Apprentice Trainee Engineer

   Mar 1997
— Mar 1998

Roles & Responsibilities :( years experience)
Worked as a apprentice trainee engineer from 21/03/97 to 20/03/98,Done operation and maintenance of 250MVA transformer,25 MVA ,20mva ,220 kv ,132 kv and 11 kv oil,sf6,air blast and vacuum circuit breaker ,testing of transformer ,relay testing and maintenance of various switch yard equipment bus, insulator, isolator etc.